初始化提交
This commit is contained in:
79
arduino-cli/libraries/BH1750/BH1750.h
Normal file
79
arduino-cli/libraries/BH1750/BH1750.h
Normal file
@@ -0,0 +1,79 @@
|
||||
/*
|
||||
|
||||
This is a library for the BH1750FVI Digital Light Sensor breakout board.
|
||||
|
||||
The BH1750 board uses I2C for communication. Two pins are required to
|
||||
interface to the device. Configuring the I2C bus is expected to be done
|
||||
in user code. The BH1750 library doesn't do this automatically.
|
||||
|
||||
Datasheet: http://www.elechouse.com/elechouse/images/product/Digital%20light%20Sensor/bh1750fvi-e.pdf
|
||||
|
||||
Written by Christopher Laws, March, 2013.
|
||||
|
||||
*/
|
||||
|
||||
#ifndef BH1750_h
|
||||
#define BH1750_h
|
||||
|
||||
#if (ARDUINO >= 100)
|
||||
#include <Arduino.h>
|
||||
#else
|
||||
#include <WProgram.h>
|
||||
#endif
|
||||
|
||||
#include "Wire.h"
|
||||
|
||||
// Uncomment, to enable debug messages
|
||||
// #define BH1750_DEBUG
|
||||
|
||||
// No active state
|
||||
#define BH1750_POWER_DOWN 0x00
|
||||
|
||||
// Waiting for measurement command
|
||||
#define BH1750_POWER_ON 0x01
|
||||
|
||||
// Reset data register value - not accepted in POWER_DOWN mode
|
||||
#define BH1750_RESET 0x07
|
||||
|
||||
// Default MTreg value
|
||||
#define BH1750_DEFAULT_MTREG 69
|
||||
|
||||
class BH1750 {
|
||||
|
||||
public:
|
||||
|
||||
enum Mode
|
||||
{
|
||||
UNCONFIGURED = 0,
|
||||
// Measurement at 1 lux resolution. Measurement time is approx 120ms.
|
||||
CONTINUOUS_HIGH_RES_MODE = 0x10,
|
||||
// Measurement at 0.5 lux resolution. Measurement time is approx 120ms.
|
||||
CONTINUOUS_HIGH_RES_MODE_2 = 0x11,
|
||||
// Measurement at 4 lux resolution. Measurement time is approx 16ms.
|
||||
CONTINUOUS_LOW_RES_MODE = 0x13,
|
||||
// Measurement at 1 lux resolution. Measurement time is approx 120ms.
|
||||
ONE_TIME_HIGH_RES_MODE = 0x20,
|
||||
// Measurement at 0.5 lux resolution. Measurement time is approx 120ms.
|
||||
ONE_TIME_HIGH_RES_MODE_2 = 0x21,
|
||||
// Measurement at 4 lux resolution. Measurement time is approx 16ms.
|
||||
ONE_TIME_LOW_RES_MODE = 0x23
|
||||
};
|
||||
|
||||
BH1750(byte addr = 0x23);
|
||||
bool begin(Mode mode = CONTINUOUS_HIGH_RES_MODE);
|
||||
bool configure(Mode mode);
|
||||
bool setMTreg(byte MTreg);
|
||||
float readLightLevel(bool maxWait = false);
|
||||
|
||||
private:
|
||||
byte BH1750_I2CADDR;
|
||||
byte BH1750_MTreg = (byte)BH1750_DEFAULT_MTREG;
|
||||
// Correction factor used to calculate lux. Typical value is 1.2 but can
|
||||
// range from 0.96 to 1.44. See the data sheet (p.2, Measurement Accuracy)
|
||||
// for more information.
|
||||
const float BH1750_CONV_FACTOR = 1.2;
|
||||
Mode BH1750_MODE = UNCONFIGURED;
|
||||
|
||||
};
|
||||
|
||||
#endif
|
||||
Reference in New Issue